Cisco 3825-VSEC-CCME/K9 Integrated Services Routers

Cisco 3825-VSEC-CCME/K9 Integrated Services Routers
Product Detailed
Related Categories:Routers
1.CISCO, H3C, Hua Wei and others relating to net work establishment. 2.100% new and original cisco 3.Good after-sell services.

Cisco 3800 Series Features

Cisco 3825/3825-NOVPN

Cisco 3845/3845-NOVPN

Physical Specifications

Dimensions (H x W x D)

• 3.5 x 17.1 x 14.7 in.• 2 rack units (2RU)• 5.25 x 17.25 x 16 in.• 3RU

Weight (minimum)

23 lb

35 lb

Rack-mounting

Yes, 19- and 23-in. options

Yes, 19- and 23-in. options

Wall-mounting

No

No

Power Specifications

AC input voltage

100-240 VAC, autoranging

100-240 VAC, autoranging

AC input frequency

47-63 Hz

47-63 Hz

AC input current

• 3A (110V)• 2A (230V)• Startup current 50A maximum (one cycle)• 4A (110V)• 2A (230V)• Startup current 50A maximum (one cycle)

AC IP input current

• 8A (110V)• 4A (230V)• Startup current 50A maximum (one cycle)• 8A (110V)• 4A (230V)• Startup current 50A maximum (one cycle)

DC input voltage

24-60 VDC, autoranging positive or negative

24-60 VDC, autoranging positive or negative

DC input current

• 12A (24V)• 5A (60V)• Startup current 50A<10 ms• 18A (24V)• 7A (60V)• Startup current 50A<10 ms

Output

• AC or DC power supply:• 210W for system• AC IP power supply:• 210W for system• 360W for IP phones (-48V)• AC or DC power supply:• 300W for system• AC IP power supply:• 300W for system• 360W for IP Phones (-48V)

Redundant power supply (RPS)

External only (Cisco RPS 675 Redundant Power System)

Internal AC, AC IP, or DC RPS

Recommended RPS unit

Cisco RPS 2300 (recommended) and RPS 675 Redundant Power System

--

Power Dissipations

Typical power dissipation (no modules)

52W (177 BTU/hr)

79W ( 269 BTU/hr)

AC without IP phone support

300W (1025 BTU/hr)

435W (1485 BTU/hr)

AC with IP phone support: System only

370W (1262 BTU/hr)

555W (1890 BTU/hr)

AC with IP phone support: IP phones

360W (1128 BTU/hr)

360W (1128 BTU/hr)

DC

325W (1100 BTU/hr)

460W (1570 BTU/hr)

Environmental Specifications

Operating temperature

32 to 104°F (0 to 40°C)

32 to 104°F (0 to 40°C)

Nonoperating temperature

-40 to 158°F (-40 to 70°C)

-40 to 158°F (-40 to 70°C)

Relative humidity (noncondensing)

5-85% noncondensing

5-85% noncondensing

Maximum operating temperature at altitude

40°C at sea level

40°C at 6,000 ft (1,800m)

30°C at 13,000 ft (4,000m)

27.2°C at 15,000 ft (4,600m)

Note: Derate 1.4°C per 1,000 ft above 6,000 ft

40°C at sea level

40°C at 6,000 ft (1,800m)

30°C at 13,000 ft (4,000m)

27.2°C at 15,000 ft (4,600m)

Note: Derate 1.4°C per 1,000 ft above 6,000 ft

Noise level (minimum)

50 dBa typical, 53 dBa maximum

56 dBa typical, 58 dBa maximum

Regulatory Compliance

Safety

• UL 60950• CAN/CSA C22.2 No. 60950• EN 60950• AS/NZS 60950• UL 60950• CAN/CSA C22.2 No. 60950• EN 60950• AS/NZS 60950

EMC

• 47 CFR, Part 15• ICES-003 Class A• EN55022 Class A• CISPR22 Class A• AS/NZS 3548 Class A• VCCI V-3• EN 300386• EN 61000• 47 CFR, Part 15• ICES-003 Class A• EN55022 Class A• CISPR22 Class A• AS/NZS 3548 Class A• VCCI V-3• EN 300386• EN 61000

Telcom

• 47 CFR, Part 68• TIA/EIA/IS-968• CS-03• RTTE Directive• 47 CFR, Part 68• TIA/EIA/IS-968• CS-03• RTTE Directive